GE® 115 Volt Heat/Cool Series Room Air Conditioner AGE07AH user guide

4-way air direction.
Consumer Support

For Normal HeatingSelect HIGH HEAT or LOW HEAT with the temp control at

For Maximum HeatingSelect HIGH HEAT with the temp control turned counter-clockwise as far as possible.

For Quieter & Nighttime HeatingSelect LOW

HEAT with the temp control at midpoint.

Additional controls and important information.

Vent Control

The vent control is located above the control

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

Safety Instructions

To open the vent, pull the lever toward you.

To close it, push it in.

Operating Instructions

Air DirectionSide-to-Side

The side-to-side air direction is adjusted by moving the lever to the left or right.

Installation Instructions

Air DirectionUp and Down

Fingertip pressure on the bank of horizontal louvers adjusts the air direction up or down.

Troubleshooting Tips

Water Drain Valve

When the outside temperature drops below

58F and the unit is set for heating, a drain valve opens up to release water from the base pan.

This is normal and prevents water from freezing in the base pan and interfering with the outdoor fan.

Consumer Support

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly.

If they are clogged with dirt or soot, they may be professionally cleaned.

Operating Instructions

Safety Instructions

Care and cleaning of the air conditioner.

Installation Instructions

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

To remove:

Open the inlet grille upward by pulling out the bottom of the inlet grille.

Using the tab, pull up slightly on the filter to release it and pull it down.

Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it.

Consumer Support

Troubleshooting Tips

DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.

To clean, use water and a mild detergent. Do not use bleach or abrasives.

Installation

Instructions

Air Conditioner

BEFORE YOU BEGIN

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problemsconsult a qualified electrician.

Read these instructions completely and carefully.

Save these instructions for local inspectors use.

Observe all governing codes and ordinances.

Note to Installer Be sure to leave these instructions with the Consumer.

Note to Consumer Keep these instructions for future reference.

Skill level Installation of this appliance requires basic mechanical skills.

Completion time Approximately 1 hour

We recommend that two people install this product.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

TOOLS YOU WILL NEED

Phillips head screwdriver

Flat-blade screwdriver

ELECTRICAL REQUIREMENTS

60 Hz grounded outlet protected with a

15-amp time delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

Ruler or tape measure

Scissors or knife

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

Installation Instructions

PARTS INCLUDED

(Appearance may vary) rail seal strip window gasket

Frame guide (2)

Sill support (2)

Window locking

Type A (16)

Type B (3)

Type C (5)

Installation Instructions

1 WINDOW REQUIREMENTS

2 STORM WINDOW REQUIREMENTS

These instructions are for a standard double-hung window. You will need to modify them for other types of windows.

The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.

All supporting parts must be secured to firm wood, masonry or metal.

The electrical outlet must be within reach of the power cord.

A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly.

To adjust for this, attach a piece of wood to the stool.

WOOD PIECES

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2? higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

For AGE07 model only.

1/2? higher than frame

22? to 36?

(With accordion panels)

(Without accordion panels)

For AGE12 model only.