GE® 115 Volt Electronic Room Air Conditioner AEM10AQ user guide

EZ Mount window installation kit included.
Unit or the Increase + / Decrease pads on the remote control to set a new time if desired.

Each touch of the Increase / Decrease ? pads on the unit or the Increase + / Decrease

pads on the remote control will set the delay time when using the Delay 124hr timer. The

Set light will turn on while setting.

Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + /

Decrease pads to set the fan speeds to Low,

Med or High. Use the Auto pad to turn Auto

To cancel the timer, press the Delay 124hr pad until the light on the Delay 124hr pad goes off.

Note: The default temperature reading on the display is degree Fahrenheit ( F). To change the display to degree Celcius (C), press the Temp Increase and Temp Decrease ? buttons together and hold for 3 seconds. Repeat the process to change back to degree Fahrenheit (F)

Use the Cool mode at Low, Med, High or Auto Fan

Speed for cooling. Use the Temperature Increase

/ Decrease ? pads to set the desired temperature between 64F and 86F in 1F increments.

An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort.

Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately

3 minutes for the compressor to start and cooling to

Cooling Descriptions

For Normal Cooling6HOHFWWKHCool mode and

High or Med fan with a middle set temperature.

For Maximum Cooling6HOHFWWKH Cool mode and High fan with a lower set temperature.

For Quieter and Nighttime Cooling6HOHFWWKH

Cool mode and Low fan with a middle set

temperature.

Energy Saver Mode

Controls the fan.

ON7KHIDQZLOOFFOHRQDQGRIIZLWKWKH compressor. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan may continue to run for a short time after the compressor cycles off.

OFF7KHIDQUXQVDOOWKHWLPHZKLOHWKHFRPSUHVVRU cycles on and off.

Fan Only Mode

Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan-only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.

NOTE: Auto Fan Speed cannot be used when in the

Fan Only Mode.

Auto Fan Speed

Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature.

If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.

NOTE: Auto Fan Speed cannot be used when in the

Fan Only Mode.

Remote Control

To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.

? Make sure nothing is between the air conditioner and the remote control that could block the

? The remote control signal has a range of up to 20 feet.

? Make sure batteries are fresh and installed correctly as indicated on the remote control.

? Remote contains a magnet allowing it to attach to metal surfaces.

Power Outage Recovery Feature

In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is restored. If the Delay 124hr feature was set, it will resume countdown. You may need to set a new time if desired.

About the controls on the air conditioner

Additional important information.

Air Direction

Use the lever to adjust the air direction left and right

Care and cleaning of the air conditioner.

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.

To clean, use water and a mild detergent. Do not use bleach or abrasives.

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

To remove:

Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45 position. Remove the filter.

Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.

DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.

How to Insert the Batteries in the Remote Control

Remove the battery cover by sliding it according to the arrow direction.

Insert new batteries, making sure that the (+) and () of battery are installed correctly.

Reattach the cover by sliding it back into position.

Use 2 AAA (1.5 volt) alkaline batteries. Do not use rechargeable batteries.

Remove the batteries from the remote control if the system is not going to be used for a long time.

Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc) or rechargeable

(ni-cad, ni-mh, etc) batteries.

Installation

Instructions

Air Conditioner

BEFORE YOU BEGIN

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special

SUREOHPVFRQVXOWDTXDOLILHGHOHFWULFLDQ

Read these instructions completely and carefully