GE® Deluxe 230 Volt Electronic Room Air Conditioner AGM18DJ user guide

3 cooling / 3 fan only speeds.
Or HIGH (F3).

ENERGY SAVER (on some models)

Controls the fan.

ONThe fan and compressor cycle on and off. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan will continue to run for a short time after the compressor cycles off.

OFFThe fan runs all the time, while the compressor cycles on and off.

This feature must be set at OFF in order to use the fan settings (on the mode control).

Consumer Support

NOTE: On some models, the ENERGY SAVER feature cannot be set on the air conditioner. It must be set using the remote control.

OFFWhen the air conditioner is on, it can be set to automatically turn off in 1 to 12 hours or

1 to 24 hours (depending on model). Each touch of the TIMER pad or the INCREASE ? /

DECREASE ? pads (depending on model) will set the timer in hours.

To cancel the timer, press the TIMER pad until the display time disappears.

Remote Control Signal Receiver

Remote Control

? To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.

? Make sure nothing is between the air conditioner and the remote control that could block the

? The remote control signal has a range of up to 21 feet.

? Make sure batteries are fresh and installed correctly as indicated on the remote control.

Lights next to the touch pads on the air conditioner control panel indicate the selected settings.

Power Outage Recovery Feature

In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is restored. If the TIMER feature was set, it will resume its countdown.

You may need to set a new time if desired.

Operating Instructions

Use the COOL mode with HIGH (F3), MED (F2) or

LOW (F1) fan for cooling. Use the INCREASE ? /

DECREASE ? pads to set the desired temperature between 60F and 86F in 1F increments.

An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort.

Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

Cooling Descriptions

For Normal CoolingSelect the COOL mode and

HIGH (F3) or MED (F2) fan with a middle set temperature.

For Maximum CoolingSelect the COOL mode and HIGH (F3) fan with a lower set temperature.

For Quieter & Nighttime CoolingSelect the

COOL mode and LOW (F1) fan with a middle set temperature.

Installation Instructions

NOTE: If the air conditioner is off and is then turned on while set to a COOL setting or if turned from a fan setting to a COOL setting, it will take approximately 3 minutes for the compressor to start and cooling to begin.

NOTE: If you switch from a COOL setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a COOL setting.

Use the FAN at HIGH (F3), MED (F2) or LOW (F1) to provide air circulation and filtering without cooling.

Since fan only settings do not provide cooling, a temperature setting will not be displayed.

Troubleshooting Tips

Vent Control

The vent control is located on the inside of the air louvers on the lower right side.

Safety Instructions

To open the vent, pull the lever toward you.

To close it, push it in.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

Air DirectionUp and Down

Fingertip pressure on the bank of horizontal louvers adjusts the air direction up or down.

Consumer Support

Features and appearance will vary.

Operating Instructions

Safety Instructions

About the controls on the air conditionermodels with control knobs.

MODE CONTROLS

Your model will have one of the above type controls.

Installation Instructions

TEMP CONTROLS

Your model will have one of the above type controls.

Troubleshooting Tips

Mode Controls

Temp Controls

HIGH COOL, MED COOL and LOW COOL provide cooling with different fan speeds.

The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.

FAN settings provide air circulation and filtering without cooling.

NOTE: If you move the mode control from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting.

Cooling Descriptions

For Normal CoolingSelect HIGH COOL or MED COOL with the temp control at midpoint.

Consumer Support

For Maximum CoolingSelect HIGH COOL with the temp control at the highest number available on your knob.

For Quieter & Nighttime CoolingSelect LOW COOL with the temp control at midpoint.

Additional controls and important information.

Energy Saver (on some models)

The energy saver switch controls the fan.

ONThe fan and compressor cycle on and off together. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied.

OFFThe fan runs all the time, while the compressor cycles on and off.

This switch must be set at OFF in order to use the fan settings (on the mode control).

Operating Instructions

Vent Control

The vent control is located above the control

Safety Instructions

To open the vent, pull the lever toward you.

To close it, push it in.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

Installation Instructions

Air DirectionSide-to-Side