500 mW Booster ANT24BNA cable (short)
NETGEAR Antenna cable
(short, medium or long)
NETGEAR Antenna cable
(short, medium or long)
Wireless unit e. g. NETGEAR
Two Antenna Ports, One Booster and Two Antennas
NETGEAR Antenna cable
(short, medium or long)
Installing the Booster with the
Optional Power Injector
Specifications
Note: As noted in the illustration below, be sure to disconnect the DC power adapter from the
ANT24BNA Booster for 802.11b, and connect it to the NETGEAR ANT24BDC Power Injector.
Current antenna
Do NOT remove
Antenna cable
(short or medium) e. g. NETGEAR
Injector NETGEAR
Wireless unit
Operating Mode
TDD Burst Mode
DC Surge Protection
600 Watts TVS @ 6VDC
Current Drain (TDD Mode)
700 mA type. @ 6VDC
Transmit Power
26.5 dBm minimum
Transmit Input Power
+ 5 dBm minimum
Transmit Ramp Up Time
3 s maximum
Receiver Gain
10 dB typical
Receiver Frequency Response
1 dB over operating range
Receiver Noise Figure
5 dB maximum
Receiver Ramp Down Time
3 s maximum
Device Size (l x w x h)
130 x 75 x 37 mm (5.1 x 3.0 x 1.5 in)
5.0 g/1.1 lbs (including DC adapter)
RF Connector Type
SMA female reverse (2x), 1 for connection to antenna,
1 for connection to ME103 wireless access point
RF Connector Impedance
50 5 Ohms
RF Connector Dielectric
Withstanding Voltage
750 VRMS maximum
RF Connector Insertion Loss
DC Block NETGEAR
2400 to 2500 MHz
500 mW Booster ANT24BNA
Frequency Range
Do NOT connect cable (short)
Description
NETGEAR 500mW Bi-directional
Booster for 802.11b, with Two
Female Reverse SMA Connectors
NETGEAR Antenna cable (medium or long)
Description
NETGEAR 500mW Bi-directional
Booster for 802.11b, with Two
Female Reverse SMA Connectors
RF Connector Recommended
Coupling Nut Torque
RF Connector Coupling Nut
Retention Force
22.7 kg (50 lb) min.
RF Connector Contact
Captivation Axial
2.27 kg (5 lb) min.
RF Connector Body
Brass per JIS H3250 C3604 BD, Gold Plated per
MIL-G-45204
RF Connector Contact
Beryllium Copper per QQ-C-530, Gold Plated per
MIL-G-45204
Operating Temperature
Description
NETGEAR PWR-10015-01 DC
Adapter Specifications
AC Input Voltage
90 to 264 VAC
AC Input Frequency
50 to 60 Hz
AC Input Current
0.4 Arms for 115 VAC
0.2 Arms for 230 VAC
AC Inrush Current
30 A-Peak for 115 VAC
50 A-Peak for 230 VAC
Full Load, 25 C, Cold Start
Output Voltage
Total Regulation
0 to 70 C (32 to 158 F)
Min/Max Load Current
0 A / 2.5 A
Storage Temperature
-30 to 80 C (-22 to 176 F)
Ripple And Noise
10% to 90%
Total Output Power
Efficiency
65% minimum @115 VAC, 60 Hz, Full Load
100 ms maximum
PVC + STEEL
Operating Temperature
0 to 40 C (32 to 104 F)
Storage Temperature
-40 to 70 C (-40 to 158 F)
10% to 90%
Designed To Meet Standards
UL, CSA, TUV
Leakage Current
0.25 mA maximum
Over Current Protection
Short Circuit Protection
Specifications
ANT24BDC Power Injector for the
ANT24BNA Booster with Two
Female Reverse SMA Connectors
Description
ANT24BDC Power Injector for the
ANT24BNA Booster with Two
Female Reverse SMA Connectors
Operation Temperature
0 to 70 C (32 to 158 F)
Frequency Range
2400 to 2500 MHz
Storage Temperature
-10 to 80 C (14 to 176 F)
2.5 A / 30 V
10% to 90%
Insertion Loss
1.5 dB maximum @ 2.4 to 2.5 GHz
Device Size (l x w x h)
88.2 x 58.9 x 33.4 mm (3.48 x 2.32 x 1.32 in)
Short Circuit Protection
PTC Fuse 2.5 A / 30 V
220 g (7.76 oz)
DC Supply Voltage
DC, 5 V to 12 V
RF Connector Type
SMA female reverse (2x), 1 for connection to antenna, 1 for connection to ME103
RF Connector Impedance
50 5 Ohms
RF Connector Dielectric
Withstanding Voltage
750 VRMS maximum
RF Connector Insertion Loss
RF Connector Recommended coupling nut Torque
RF Connector Coupling nut retention force
22.68 kg (50 lbs.) minimum
RF Connector Contact captivation axial
2.27 kg (5 lbs.) minimum
RF Connector Body
Brass per JIS H3250 C3604 BD, Gold Plated per MIL-G-45204
RF Connector Contact
Beryllium Copper per QQ-C-530, Gold Plated per
MIL-G-45204
Aluminum Alloy
Description
Statement of Conditions
In the internal function, and/or reliability, NETGEAR reserves the right to make changes to the products described in this document without notice. NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.
Federal Communications Commission (FCC) Compliance Notice:
Radio Frequency Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna, (2) Increase the separation between the equipment and receiver, (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected, (4) Consult the dealer or an experienced radio/TV technician for help.
Federal Communications Commission (FCC) Radiation Exposure Statement
To ensure compliance with the FCC's RF Exposure requirements for saftey, all omni-directional antennas (Netgear
ANT24O5) must be installed to provide a separation distance of at least 20 cm from a person.
The panel antennas (Netgear ANT24D18) must be fixed mounted on a perman